For a month the Iomega would only wake up when its barrel plug sat at exactly the right angle, and the woman in charge of storing the Sidmouth local-history group's scanned documents was aware of this. Then one morning, however, the Iomega drive was cold and completely lifeless. A spare cable out of her drawer changed nothing, so she brought over the drive and adapter bagged together and asked one single question: could the old adapter have shorted the board?

Outcome verified by the customer Anonymised throughout

Sound familiar? Talk to us.
0800 6890668

In plain English.

The answer was "yes". A barrel plug that needs to be seated just so is arcing at the joint, and the final weeks of a dying power adapter are spent with erratic dips and spikes instead of a consistent twelve volts. The board of the drive will take that first hit, since the protection diode on the board absorbs as much as possible before failing shorted. That failure causes a drop in the supply rail. Death occurs suddenly on the outside but platters remain intact inside.

The tools this job took.

See how your case runs →
SystemThe part it playedWhy we rate it
ACE Lab PC-3000 ExpressTraced the short to the protection parts; kept the board's identity safeTalks to a drive through the maker's own commands, not just standard ATA
PC-3000 Data ExtractorHandled the copy the first time in a month the disk saw honest powerThe PC-3000's imager, taking its orders from the firmware side
UFS Explorer Professional RecoveryReassembled folders and files from the image once repairs heldHandles the harder filesystems well — APFS, ReFS, XFS, ZFS and Btrfs

On the bench.

01

Test the accused adapter, not just the drive

Both of the units were sent to our bench for testing. The adapter's output was unstable and also exceeded normal limits under load, as we had previously suspected. On the drive, we found a dead short at the twelve-volt input and located some burn marks around the protective diode, which are typical of damage from electrical spikes, not from age.

02

Replace the burnt parts, keep the identity

The failed parts were removed and new (and good) replacements installed, while the board retained the same unique ROM throughout, which contains the calibration information for that particular mechanical device. A hard disk must have its own memory in order to read the data from its own platters.

03

Clean power at last, then a straight read

Once power was supplied from the regulated source, the drive identified itself as usual. The drive provided the defect table(s) and the imaging pass ran to the end with no "bad" regions. Electrical failures that kill a drive usually only go skin-deep, and when it comes to the platters, they have a tendency to "sleep" through electrical issues.

How it ended.

All of her archive came back, and we checked every single scan in it as per her request, one-by-one against the group's own index. The adapter was retired to the bin as part of a ceremonial goodbye, and in written form she received the answer to her question.

It's worth keeping in mind: If you have a plug that can only function at one angle, this is a warning; it's not a "knack". Make sure you retire a failing adapter (and get rid of it) before the failing adapter gets rid of the drive.

Sound like your drive?

In every single case here, you are being told the same thing: power off your device, take a free diagnostic test, then decide what to do next.

0800 6890668