The bench is open for new cases · Mon–Fri, 9am–5:30pm Need it fast? Ring 0800 6890668
EDR Exeter Data Recovery 0800 6890668 Start my case
EDR / Casebook / One Drive Clicking, One Quietly Fading

From the bench · Desktop externals · EDR-2025-2334

One Drive Clicking, One Quietly Fading.

An office refit sent us both of these in one box. The old Iomega came off a cupboard shelf for one archive copy and crawled through it — ten minutes a folder, then it drops off the screen — put down to just its age, surely. Then the newer 2TB desktop drive followed the furniture over: knocked from the top of a tower case, after which it ticks away to itself and nothing finds it.

Outcome verified by the customer Anonymised throughout

Sound familiar? Talk to us.
0800 6890668

In plain English.

The office had ranked them by ear, and the ear gets this backwards. The quiet Iomega was the urgent one: its reads had grown slower than the interface would tolerate, so Windows kept cutting it off mid-copy — a drive failing politely, and losing a little more with every power-up. The clicking WD was the graver fault but the stabler patient: heads damaged by the fall cannot find their bearings on the platters, and no amount of shelf time makes that worse. Sound tells you something is wrong; it will not tell you what to do first.

The tools this job took.

See how your case runs →
SystemThe part it playedWhy we rate it
DeepSpar Disk Imager 4Read the WD after its surgery — heads mapped, strongest surfaces cleared firstImages by head map — timeouts, resets and power-cycling managed per head
PC-3000 Data ExtractorNursed the Iomega through one full pass, every stall capped and loggedThe PC-3000's imager, taking its orders from the firmware side
R-Studio TechnicianReassembled the folder structure of each drive from its finished imageHandles most filesystems; dependable RAID reassembly

On the bench.

01

Two queues, set by physics rather than noise

Arriving together bought them nothing: each was sized up alone. Left unpowered, the ticking WD would be no worse next week than today, which made it the one case where waiting was safe. The Iomega enjoyed no such truce — every hour under power cost it sectors for good — so it took the bench first, with the WD shelved behind it.

02

The Iomega first, and against the clock

Its enemy was the stall, so the stall was tamed: each read got a short fixed allowance, and any sector overrunning it was logged and set aside for a gentler second visit. Nothing dropped off a bus; nothing restarted from zero. The failures that had wrecked every office copy shrank into list entries, and the bulk of the old drive came across steadily.

03

Donor parts for the WD, and no hurry

A replacement head stack was the WD's only way back, so a matched donor went in under clean air and each head was graded first. The landing had scored one surface; the rest were sound and gave everything, the scored band what it could.

How it ended.

The results inverted the office's expectations. The written-off Iomega came back close to complete; the WD lost the scored stretch of one surface, and the client folders sitting on it — named in a written list, not glossed over.

Worth remembering: Never triage drives by their noise. The quiet ones often lose ground fastest — and lose it for good.

Sound like your drive?

Every case here points the same way: power the device down, take the free diagnosis, then make your decision.

0800 6890668